Industrial lab meters

Features

  • LCD Display
  • Dual display of the readings for CO and Temperature
  • CO range: 0 ~ 1,000ppm with resolution of ±1ppm
  • Temperature range: - 20~50 ºC with resolution of ±0.1 ºC
  • Easy to calibrate at 100ppm or 500ppm
  • Application

  • Indoor air quality (IAQ) instrument measuring the carbon dioxide (CO) and Temperature.
  • Features

  • 3 Independent CO2, humidity and temperature sensors
  • User operated CO2 calibration
  • CO2 Measurement range: 0~9999 ppm
  • CO2 Accuracy: ± 60ppm, ± 5% of reading
  • USB data logger: 50,000 records
  • Easy- to-Use PC software for parameter settings and data analysis
  • Internal CO2 alarm buzzer
  • Application

  • Indoor air quality (IAQ) instrument measuring the carbon dioxide (CO2), Relative Humidity (RH) and Temperature.
  • Features

  • Can be displayed simultaneously formaldehyde, temperature, humidity, easy to monitor
  • Occupational safety monitoring shows TWA (8 hours) and STEL (15 mins)
  • Use high-precision electrochemical sensors
  • The maximum / minimum / average hold
  • Data hold
  • Formaldehyde maximum and minimum alarm value setting
  • Application

  • Instrument measuring the HCHO, Relative Humidity and Temperature.
  • Features

  • Fast response telescoping probe with Large LCD display.
  • Air Flow (Volume) Range: 0~9999 CMM/CFM
  • Resolution: - 0.1CMM
  • Air velocity measurement: 0.01 to 25.00 m/s
  • Resolution: - 0.01 m/s
  • Air flow volume
  • Displays air (wind) speed in meters/second, feet/minute, kilometres/hr, knots, and miles/hr
  • Displays maximum and minimum readings and holds any reading
  • Manual Data Memory and read function
  • Dew point, Wet Bulb calculation
  • Application

  • HVAC system performance
  • Commissioning
  • Plant maintenance
  • The HEAT STRESS WBGT METER is quick-response with accurate measurement for the effects of temperature, humidity, and direct or radiant sunlight.

    In order to measure the WBGT index, refer to the following regulations: ISO7243: Hot environments. Estimation of the heat stress on working man ISO7726: Ergonomics of the thermal environment-instruments for measuring physical quantities OSHA: Occupational Safety and Health Administration JISHA: Japan Industrial Safety and Health Association

    Features

  • Quick-response capacitance sensor, accurate measurement for wet bulb globe temperature(WBGT), black globe temperature(TG), humidity(%RH), air temperature(TA), wet bulb(WET) and dew point(DEW)
  • LCD display with LED backlight
  • WBGT alarm setting
  • Data logging capacity: 12000 records, USB PC serial interface
  • Sampling interval: Max 24 hours; Min 1 Second
  • Application

  • • This instrument is ideal for the athletic trainers, military, occupational (Industrial) hygienists, outdoor worker and the sports medicine specialists
  • Features

  • 3½ digits LCD display with maximum reading of 2000.
  • Measuring the Solar radiation emitted by the sun.
  • Range: - 2000 W/m2, 634BTU
  • Display units: W/m2 (Watts per square meter) or BTU.
  • Data Hold/ MAX/MIN functions
  • Application

  • Meteorology applications
  • Agriculture applications
  • Physics and optical laboratories
  • Solar radiation measurement
  • Solar transmission measurement
  • Identify high performance windows
  • Helpful to set up Solar PV Panels at optimum angles of incidence
  • Light Intensity Measurement for the car windows
  • Features

    Application

  • 3½ digits LCD with maximum reading 2000
  • According to JISC1609:1993 and CNS 5119 general A class specifications
  • Measuring range:- 200, 2000, 20000, 200000 Lux 20,200, 2000, 20000 Foot-candle Accuracy: - +/- 3% of reading
  • Spectral response close to CIE luminous spectral efficiency
  • Measuring intensities of illumination in unit of Lux or Foot-candle
  • Application

  • Measuring lights source include all visible range
  • Warehouses, factories, office buildings, restaurants, schools, libraries, hospitals, building security and parking stations
  • Features

  • LCD display with maximum reading 3999
  • Measuring range: 38mV/m to 11V/m
  • Frequency Range: 50MHz to 3.5GHz or 10MHz to 8GHz Resolution: 0.1mV/m
  • Application

  • Office, Institute, DTH service, IT Services, E&TC Applications
  • Features

  • LCD display
  • Single Axis/ Tri Axis
  • Resolution:-0.1/0.01mG
  • Range:-20/200/2000 mG
  • With data logger/ Without Data-logger
  • Application

  • Used to measure EMF of low frequency 30Hz to 2000Hz
  • Used in Power line, computer monitors as well as domestic devices
  • Features

  • Battery capacity: 0 to 500A/h
  • Resistance range: 40mΏ to 40Ώ
  • Voltage Range: 4.0V to 40.0V
  • USB Interface with software
  • Application

  • Ideal tester for automotive, UPS maintenance and telecommunication applications
  • Features

  • Simultaneous power and power quality measurements: Voltage, currents, power factor, powers, ingoing, outgoing power, voltage anomalies, voltage unbalance, phase angle, voltage and current harmonics
  • Application

  • USB interface
  • Features

  • Large LCD 6 digits with backlit
  • Available with contact and non-contact
  • Measuring by the output of red visible-spectrum light
  • Measurement distance: 40~500mm
  • USB data logger up to 30,000 data
  • Application

  • Various types of equipment such as conveyors, cooling equipment, dryers, elevators, windmills, rotary feeders and grinders